A simple prototype for pulsatile blood flow using an adjustable centrifugal pump

Nil Harmandar1,
Hayriye Serra Altınoluk2
1Nesibe AYDIN Educational Instutitions
2Muğla Sıtkı Koçman University
Published:December 31, 2024

Abstract

Heart-lung machines used in open heart surgeries pump the necessary blood with two different types of pumps integrated into them. These pumps are roller or centrifugal pumps. While roller pumps are preferred more frequently in cardiac surgeries due to their ease of use and relatively low cost, centrifugal pumps are preferred in cases where long-term mechanical cardiac support or long-term oxygenation is required. Centrifugal pumps are suitable for longer-term use due to their advantage of causing less damage to the shaped elements of the heart (thrombocytes, leukocytes and erythrocytes) compared to roller pumps. Other flow types of heart-lung machines are pulsatile and non-pulsatile flows which may influence the side-effects of these machines on human body. While non-pulsatile blood flow pumps blood into the body continuously at a constant pressure, pulsatile blood flow pumps blood intermittently, imitating the heart's beating pattern. Therefore, pulsatile blood flow is more physiological and has many benefits over non-pulsatile flow, such as reducing inflammation that may occur in the body and thus reducing the side effects of the heart-lung machine. Although there are many studies on the pulsatile flow using roller pumps, there is no device in daily use that will provide an adjustable pulsatile flow using a centrifugal pump. There are very few experimental studies on centrifugal pumps providing pulsatile flow in which the frequency and flow rate of the pulsatile flow was often kept constant. Currently, no device that can adjust the desired frequency and flow rate has yet entered the routine use. Thus, the aim of this project is to design a simple prototype of such a centrifugal blood pump that will provide pulsatile blood flow which will be adjusted in terms of frequency and flow rate.

Keywords
Cardiopulmonary bypasscentrifugal heart pumppulsatile cpb flowprototype device

References

  1. 1.Mohammadzadeh, A., Jafari, N., Hasanpour, M., Sahandifar, S., Ghafari, M., & Alaei, V. (2013). Effects of pulsatile perfusion during cardiopulmonary bypass on biochemical markers and kidney function in patients undergoing cardiac surgeries. American Journal of Cardiovascular Disease, 3(3), 158.
  2. 2.Sievert, A., & Sistino, J. (2012). A meta-analysis of renal benefits to pulsatile perfusion in cardiac surgery. The Journal of ExtraCorporeal Technology, 44(1), 10.
  3. 3.Gu, Y. J., van Oeveren, W., Mungroop, H. E., Epema, A. H., den Hamer, I. J., Keizer, J. J., Leuvenink, R. P., Mariani, M. A., & Rakhorst, G. (2011). Clinical effectiveness of centrifugal pump to produce pulsatile flow during cardiopulmonary bypass in patients undergoing cardiac surgery. Artificial Organs, 35(2), E18-E26.
  4. 4.Nishida, H., Uesugi, H., Nishinaka, T., Uwabe, K., Aomi, S., Endo, M., Koyanagi, H., Oshiyama, H., Nogawa, & Akutsu, T. (1997). Clinical evaluation of pulsatile flow mode of Terumo Capiox centrifugal pump. Artificial Organs, 21(7), 816-821.
  5. 5.Shahandashti, F. J., Asadian, S., Habibi, N., Gorjipour, F., Jalali, A., & Toloueitabar, Y. (2023). Pulsatile versus non-pulsatile perfusion in coronary artery bypass operation: The comparison of laboratory and clinical outcomes. Perfusion, 38(5), 1053-1061. Khare, S. K., & Bajaj, V. (2020). Time–frequency representation and convolutional neural network-based emotion recognition. IEEE transactions on neural networks and learning systems, 32(7), 2901-2909.
Download PDF
Cite This Article
Harmandar, N., Altınoluk, H. S. (2024). A simple prototype for pulsatile blood flow using an adjustable centrifugal pump. *The European Journal of Research and Development*, 4(4), 328-337. https://doi.org/10.56038/ejrnd.v4i4.589

Bibliographic Info

JournalThe European Journal of Research and Development
Volume4
Issue4
Pages328–337
PublishedDecember 31, 2024
eISSN2822-2296