Abstract

Air flow is of great importance in terms of energy efficiency and homogeneity of the cooled package temperatures in open type refrigerated display cabinets (RDCs). Deflectors are critical components for air curtains which are provides air directioning to air channel and grill. A new deflector structure was investigated to increase the performance of the air curtain in this study. Current design deflector structure (Design 1) and new design deflector structure (Design 2) were compared for temperatures of air off-air on and energy consumption parameters. Airflow in the new design deflector structure   was tested under Class-3 conditions (25 °C temperature and %60 relative humidity) with ISO 23953-2 2015 standard. According to the results obtained the data compared with the current design deflector structure. The thermal performance has been increased by reducing the temperature of the air off by 1.2 °C on average, the air on temperature by an average of 2.05 °C and the average package temperature by %17.8 with the new deflector design. Cooling performance was increased using new deflector structure with effective airflow between the air off and air on. In addition, thanks to Design 2, the annual energy consumption of RDC has been reduced by 10.17% and accordingly the CO2 emissions released to the environment have been reduced at the same rate.

Keywords
RefrigerationOpen type refrigerated display cabinetDeflectorAir curtainEnergy Efficiency

References

  1. 1.Laguerre, O., Operation (2015), Design and performance of retail display cabinets. Evans, J,A, Foster, A,M, editors. Sustainable Retail Refrigeration, UK: Wiley Blackwell, 17-31.
  2. 2.Chen, Y,G, (2009). Parametric evaluation of refrigerated air curtains for thermal insulation. International Journal of Thermal Sciences, 48(10), 1988-1996.
  3. 3.Wu, X, Gao, Z, Meng, H, Wang, Y, Cheng, C. (2020). Experimental study on the uniform distribution of gas-liquid two-phase flow in a variable-aperture deflector in a parallel flow heat exchanger. International Journal of Heat and Mass Transfer, 150, 119353.
  4. 4.Li, X., Wu, F., Tao, Y., Yang, M., Xu, R., Vainchtein, D. (2022). Numerical investigation of flow deflectors for the improvement of condensing air flux through the air-conditioning unit on high-velocity trains. Building and Environment, 215, 108949.
  5. 5.Gao, R., Li, H., Li, A., Liu, K., Yu, S., Deng, B. (2019). Applicability study of a deflector in ventilation and air conditioning duct tees based on an analysis of energy dissipation. Journal of Wind Engineering and Industrial Aerodynamics, 184, 256-264.
  6. 6.Hadawey, A, F, Jaber, TJ, Ghaffar, WA, Hasan, AHAM. (2012). Air curtain design optimization of refrigerated vertical display cabinet using CFD. International Journal of Scientific Engineering and Technology,1(4), 76-88.
  7. 7.Shi, J, Qu, X, Qi, Z, Chen, J. (2011). Investigating performance of microchannel evaporators with different manifold structures. International Journal of Refrigeration, 34(1), 292-302.
  8. 8.Redo, MA, Jeong, J, Yamaguchi, S, Saito, K, Kim H. (2020). Characterization and improvement of flow distribution in a vertical dual-compartment header of a microchannel heat exchanger. International Journal of Refrigeration, 116, 36-48.
  9. 9.Wang, Y., Qian, S., Xu, J., Li, L., Dou, X., Li, X., Yan, G., Yu, J., (2021). Numerical study on the air curtain characteristics of a dual-temperature open display cabinet. International Journal of Refrigeration, 126, 23-34.
  10. 10.Li, X., Zhang, Z., Liu, H., Hu, X., Liu, S., Xu, Z., Wang, Q. (2022). Performance of an open refrigerated display cabinet with two air curtains. Applied Thermal Engineering, 212, 118549.
  11. 11.Yuan, P, Zeng, QH, Wu, YX, Lu, YL, Hu, CL, Sun, H, C, Tao, W, Q. (2022). Experimental study of using aerofoils in a refrigerated display cabinet. International Journal of Thermofluids, 14, 100140.
  12. 12.Cengel, AY, Boles, AM. (2008). Thermodynamics an engineering approach. İstanbul, TURKEY: Literatur Publishing.
  13. 13.Hayes, FC. (1969). Heat transfer characteristics of air curtain. ASHRAE Transactions, 153-167.
  14. 14.Commission Delegated Regulation (EU) 2019/2018 of 11 March 2019 supplementing Regulation (EU) 2017/1369 of the European Parliament and of the Council with regard to energy labelling of refrigerating appliances with a direct sales function. Office Journal of the European Union. Available from: http://data.europa.eu/eli/ reg_del/2019/2018/ojLink
  15. 15.Tripathi, R., Tiwari, G, N, Dwivedi, V,K, (2016). Overall energy, exergy and carbon credit analysis of N partially covered photovoltaic thermal (PVT) concentrating collector connected in series. Solar Energy, 136, 260-267.
  16. 16.Zhijuan, C, Xuehong, W, Yanli, L, Qiuyang, M, Wenhui, Z. (2013). Numerical simulation on the food package temperature in refrigerated display cabinet influenced by indoor environment. Advances in Mechanical Engineering, 5, 1-7.
  17. 17.Wu, X.,H., Chang, Z.,J., Ma, Q.,Y., Lu, Y.,L., Yin, X.,M., (2016). Optimization and investigation of the effect of velocity distribution of air curtains on the performance of food refrigerated display cabinets. Heat and Mass Transfer, 52, 1633-1647.
Download PDF
Cite This Article
Öder, M., Demirpolat, H., Erdoğmuş, F. N., Erten, S. (2022). Development of Deflector Structure and Effects on Performance: Refrigerated Display Cabinet Application. *The European Journal of Research and Development*, 2(4), 155-168. https://doi.org/10.56038/ejrnd.v2i4.190

Bibliographic Info

JournalThe European Journal of Research and Development
Volume2
Issue4
Pages155–168
PublishedDecember 31, 2022
eISSN2822-2296